• Medical Fingertip Finger Pulse Oximeter
  • Medical Fingertip Finger Pulse Oximeter
  • Medical Fingertip Finger Pulse Oximeter
  • Medical Fingertip Finger Pulse Oximeter

Medical Fingertip Finger Pulse Oximeter

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Pulse Oximeter
Certification: CE, FDA, EEC, MSDS, ISO13485
Group: All Age
Medical Device Regulatory Type: Type 1
Medical Devices Reg./Record No.: Stxb20140016
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
Pulse Oximeter
Medical Devices Ad. Approval No.
Stxb20140016
Transport Package
Individually Box Packaging
Specification
ISO, CE
Trademark
ecg paper
Origin
USA
HS Code
901890100
Production Capacity
1000000PCS/Year

Product Description

fingertip pulse oximeter  is Reliable accuracy and durability, Small and light weight, convenient to carry is Widely used in hospital, home healthcare, oxygen bar, community medical centre, alpine area, sports healthcare etc.
- Two Color OLED Display, four display modes.
- 4-Direction Display adjustable.
- Low voltage indicator, Real-time spot-checks.
- Low power consumption,50 hours continuous to work.
- Low Perfusion ≤0.4%
- Automatic power off when no signal
- Small and light weight, convenient to carry
Color OLED display, screen resolution: 128*64,four directions adjustable
SpO2 and pulse monitoring with SpO2 waveform display
Low -power consumption, continuously work for 50 hours
Small in size, light in weight, and convenient to carry
Low voltage alarm display, auto power off
Runs on standard AAA batteries 
Two parameters:SPO2, Pulse Rate.

SPo2
Measurement range: 70%-99%
Accuracy: ±2% on the stage of 70%- 90%, unspecified(<70%)for SPo2
Resolution: ±1%
Low perfusion: <0.4%
PR
Measurement range: 30BPM-240BPM
Accuracy: ±1BPM or ±1%(the larger one)

Power: two AAA1.5V alkaline batteries
Power consumption: below 30MA
Automatic power-off: the product shuts down automatically after nosignal for 8 seconds
Dimension: 62mm*32mm*33mm
Operation environment
Operation temperature: 5ºC-40ºC
Storage temperature:-10ºC-40ºC
Ambient humidity: 15%-80% on operation 10%-80% in storage
Air pressure: 70kPa-106kPa
Declaration: EMC of this product comply with IEC60601-1-1 standard