• Neonate Infant Bubble CPAP with Air Compressor for Ventilator
  • Neonate Infant Bubble CPAP with Air Compressor for Ventilator
  • Neonate Infant Bubble CPAP with Air Compressor for Ventilator
  • Neonate Infant Bubble CPAP with Air Compressor for Ventilator
  • Neonate Infant Bubble CPAP with Air Compressor for Ventilator

Neonate Infant Bubble CPAP with Air Compressor for Ventilator

Type: Surgical
Kind: Bubble CPAP with Air Compressor
Certification: CE, FDA, ISO13485
Group: Adult
LCD Display: With LCD Display
Transport Package: Box
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2017

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
CPAP for Ventilator
Specification
universal
Trademark
OEM
Origin
China
HS Code
3006500000
Production Capacity
10000000PCS/Month

Product Description

NCPAP Nasal Continuous Positive Airway Pressure(NCPAP) is a form of positive airway pressure ventilation with nasal prongs to keep the airways continuously open in people who are able to breathe spontaneously. Pigeon AD series commit to respiratory care for premature, neonate, pediatric with nasal prongs and are widely applied in ICU,NICU,PICU,etc.


Infant CPAP is a sort of special medial equipment for support of babies breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics, use it on the course of ventilation treatment of CPAPNasal-CPAP) for premature infant, neonate, infant to children over 14 years old.
2) Characteristics of Performance:
Compact system structure, all main machine, humidifying machine, air compressor(matching) are all-in-one, which can effectively save space;
Built-in type air and oxygen mixture, combining with real time monitoring of oxygen concentration(guarantee to use over two year s of system oxygen battery), carrying out dual-guarantee on use safety of oxygen, especially for avoiding to the caused complication for wrong use method of oxygen as to premature infant, neonate.
With highly exquisite adjustment of CPAP, It fully guarantees safety of patients that combined system pressure monitoring with safe valve;
It can also expand various of types to sue of infant NCPAP;
It is allowed to choose electronic control high-temperature or automatic control humidifying machines, for making sure that the system keeps on the best humidifying state;
Light pipeline and snuffle, which can reduce resistance of breath pipelines, decrease work of breathing of patients, matching systems fixed equipment, then it can decrease oppression of patients head and face and damage of nasal septum;
Fit for PIICUNICUPICU of department of pediatrics, wards and so on.
3) Technology Parameter
Oxygen percent control (air mixer): 21%-100%
Flow control: 0-18LPM
Continuous CPAP control: 0.1KPa-1.0KPa(1CMH2O-10CMH2O);
Monitoring
Pressure monitoring: 0-3KPa(0-30CMH2O)
Oxygen concentration monitoring: 21%-100%
Pressure safe valve: Pressure is more than 1.5 of control parameter in pipeline of equipment, safe valve will start automatically.
Alarm
Pressure difference alarm: Pressure difference of oxygen supply is between 0.05MPa and 0.12MPa, alarm by sound;
Battery low-voltage alarm: LCD shows LOW BATTERY when voltage reduces to 6.8V0.5V, then alarming(alarm by sound).
General Parameter
Dimension of main machine: WxHxD 24.7cm* 17.5cm*21cm
Weight of main machine: About 6kg
Air source supply: 0.3MPa-0.4MPa
flow control  0-18LPM
oxygen concentration monitoring 21%-100%
pressure monitoring 0-3Kpa (0-30CMH20)
continuous CPAP control 0.1Kpa-1.0Kpa (1CMH2O-10CMH2O)
FiO 2
21%-100%(± 3%)
CPAP
0-10cmH2O
Flow
2-18LPM
Noise
≤55dB(A)
Power source
AC220V/110V,50-60Hz
Gas source
Alarm
When gas supply pressure difference>0.1 MPa
Humidifier
Standard:PN-2000F;
Optional:PN-2000FB,PN-2000FC850
Air compressor
PN-3000(Optional)
Trolley
Yes


Neonate Infant Bubble CPAP with Air Compressor for Ventilator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now